FM-200 (FM200) and clean-agent fire suppression systems: supply and installation in Riyadh and across Saudi Arabia
TALS supplies and installs FM-200 (HFC-227ea) and other clean-agent fire-suppression systems for server rooms, archives and control rooms in Riyadh and across Saudi Arabia, with design and quantity calculations by our in-house engineering team to NFPA 2001 and ISO 14520.
Saudi Civil Defense's information-centre regulation calls for a complete automatic alarm and automatic extinguishing system using suitable gases that do not damage the room, and we handle supply, installation, testing and maintenance.
What we deliver
- Supply of FM-200 and other clean-agent systems from multiple international brands.
- Design and calculation of agent quantity and cylinder count by our in-house engineering team, to NFPA 2001 and ISO 14520.
- Installation of cylinders, piping and nozzles, the detection and release control panel, abort and manual release stations, linked to the fire alarm and the air-conditioning shutdown.
- Room integrity (door fan) testing.
- Commissioning and testing after installation, with the calculations and test report handed over.
- Maintenance contracts, and cylinder refills for the systems we install on our projects.
- Replacement of old Halon and FM-200 systems.
The official requirement
«١. يجب ان تشمل تجهيزات الحماية من الحريق نظام كامل للإنذار الآلي والاطفاء التلقائي بإستخدام غاز الهالون أو الغازات المغمده المناسبه التي لا تحدث تلفيات بالمكان نتيجة الاستعمال.»Fire-protection equipment must include a complete automatic fire alarm and automatic extinguishing system using halon or suitable flooding gases that cause no damage to the place when used.
«مع مراعاة عدم البدء في التنفيذ إلا بعد الحصول على موافقة الدفاع المدني والجهات المختصة»Work must not start until Civil Defense and the competent bodies have approved it.
Source: Same regulation, Article 14, item 8, p.7.
Both quotes keep the regulation's original spelling. The regulation does not name FM-200; the manufacturer lists FM-200 as an accepted halon replacement.
Sectors we serve
We also serve control and equipment rooms in oil & gas, airports and giga-projects.
- Data centres, server and telecom rooms — Article 14 of the information-centre regulation calls for automatic gas extinguishing, with detection under raised floors and above false ceilings.
- Archives and records centres — the same regulation covers documents kept on paper and microfilm, not only on computers.
- Banks' data rooms — server rooms and disaster-recovery sites of banks and financial firms, which can fall under the regulation's definition of an information centre.
- Hospitals — the hospitals regulation asks for an automatic system using other agents in «أماكن الخطورة الخاصة حيث لا يمكن استخدام المياه» (special-risk areas where water cannot be used).
- Hotels' computer rooms — the hotels regulation asks for automatic extinguishing with halon alternatives in computer and sensitive-equipment rooms of buildings with occupancy over 250.
- Electrical, UPS and generator rooms — Civil Defense names CO2 for these rooms; clean agent is a design option for rooms staff enter, with the design submitted to Civil Defense.
- Factory and industrial control rooms — the Civil Defense industrial-building guide lists «الأنظمة النظيفة (904.10)» (clean-agent systems) among alternative extinguishing systems.
- Universities and schools — server rooms and data centres in educational buildings; the educational-building guide lists the same clean-agent systems (904.10).
Guides
Which agent, and why
- FM-200 (HFC-227ea): reaches extinguishing concentration in 10 seconds or less, is electrically non-conductive and leaves no residue, according to the manufacturer's bulletin. That is why it is used in server, telecom and sensitive-equipment rooms.
- FK-5-1-12 (the agent 3M sold as Novec 1230): 3M ended production at the end of 2025; the same agent is available from other makers.
- Inert gas (IG-541 and similar): often chosen for large rooms and archives; it needs more cylinders and pressure-relief venting.
- CO2: named by the hotels regulation for electrical, generator and transformer rooms, and used in rooms that are normally unoccupied.
Questions procurement teams ask
What is an FM-200 system?
FM-200 is Chemours' trademark for HFC-227ea, a clean extinguishing agent stored in cylinders and discharged through a pipe network and nozzles into the protected room. The manufacturer states it reaches extinguishing concentration in 10 seconds or less and leaves no residue (Chemours bulletin, p.3).
Does Saudi Civil Defense require gas suppression in server rooms and data centres?
Yes, for information centres: Article 14/1 of the Civil Defense information-centre regulation requires a complete automatic alarm and automatic extinguishing system using halon or suitable gases that do not damage the place. It does not name FM-200; the agent is chosen in the design.
Is FM-200 banned in Saudi Arabia after the Kigali Amendment?
No. Kigali is a phase-down, not a ban: Saudi Arabia ratified it on 10 September 2025, it entered into force on 9 December 2025, and HFCs, including HFC-227ea, are frozen from 2028 and cut by 85% by 2047 (International Institute of Refrigeration; Montreal Protocol Annex F).
Has Novec 1230 been discontinued, and what replaces it?
3M's 10-K annual report (February 2026) says 3M completed its exit of PFAS manufacturing at the end of 2025, so 3M Novec 1230 is no longer made. The same agent, FK-5-1-12, is available from other makers; confirm the right replacement for your system with the system manufacturer.
Is FM-200 safe for people in the room?
The manufacturer describes it as safe for occupied spaces, and its no-observed-adverse-effect level (NOAEL) is 9% (Chemours bulletin, p.4). We design the agent concentration to NFPA 2001.
What is the difference between FM-200 and CO2?
The hotels regulation names CO2 for electrical, generator and transformer rooms (section 11/6/ت, p.19), and CO2 is used in rooms that are normally unoccupied. FM-200 is designed for rooms where people work, such as server and control rooms; see the comparison guide.
Do I need Civil Defense approval before installation?
Yes. Article 14/8 of the information-centre regulation requires the drawings to be submitted and says work must not start before Civil Defense and the competent bodies approve. Our in-house engineering team prepares the calculations and drawings you need for the submission.
What happens after installation?
Article 14/3 of the same regulation requires a practical test after installation in the presence of a representative of the competent body. Before that we commission the system and run the room integrity test, and we hand you the test report.
How often must an FM-200 system be checked?
Article 6 of the information-centre regulation makes the person responsible for the facility answerable for monthly checks and periodic tests every three months. We offer maintenance contracts and refill cylinders for the systems we install; the maintenance guide has the details.
What is a room integrity (door fan) test?
It measures air leakage from the protected room to confirm the agent will hold its extinguishing concentration after discharge. The Ministry of Health's 2018 prequalification for gas-suppression contractors required it for every protected room, to NFPA 2001.
Do you replace old Halon or FM-200 systems?
Yes. The Civil Defense fire-systems page states that halon is on its way to an international ban and will be replaced by alternative agents. We survey the existing system first, then choose the replacement agent and design the new system.
How much does an FM-200 system cost?
Cost depends on room size and number, agent type, room sealing works, and the detection and interface work. Send the room dimensions and site type by WhatsApp or the quote form, and we calculate the quantity and send you a quotation.