FM-200 — Hotels

FM-200 fire suppression for hotel computer rooms in Riyadh, supplied and installed

The Civil Defense hotels regulation requires computer and sensitive-equipment rooms in hotels with occupancy over 250 people to have automatic extinguishing using halon alternatives.

TALS supplies and installs FM-200 and clean-agent systems for these rooms in Riyadh and across Saudi Arabia.

What we deliver

  • Supply and installation of FM-200 and clean-agent systems from multiple international brands, sized for small rooms.
  • Design and agent quantity calculations by our in-house engineering team to NFPA 2001 / ISO 14520.
  • Control and release panel linked to the hotel fire alarm and to HVAC shutdown.
  • Room integrity (door fan) test before handover.
  • Maintenance contracts, and cylinder refills for our own projects.
  • Replacement of old Halon and old FM-200 systems.
  • Works scheduled to keep guest disruption low.

Request an FM-200 quotation

Only name and mobile are required.

Send files (BOQ, drawings) later to info@tals.sa or WhatsApp.

Prefer to talk first?

Projects line

055 544 3168

📞 Call

info@tals.sa

The official requirement

«ج- تجهز غرف الكمبيوتر والأجهزة الدقيقة إن وجدت بنظام الإطفاء الآلي باستخدام الوسائل البديلة لغاز الهالون بحيث لا تحدث تلفا في التجهيزات ولا تشكل خطرا على البيئة والصحة العامة.»

"Computer and sensitive-equipment rooms, where present, shall be fitted with an automatic extinguishing system using halon alternatives that do not damage the equipment or harm the environment or public health." It applies under item 6, automatic extinguishing systems "in buildings with occupancy over 250 persons".

Source: Saudi Civil Defense, "Regulation of Safety Requirements, Prevention, Alarm and Fire-Fighting Equipment for Hotels, Youth Hostels and Similar Facilities", Section 11 / 6 / c, p.19.

Sector specifics

  • Typical rooms: server/IT room, telecom (PABX) room, security and CCTV control room, building management system (BMS) room.
  • Usual agent: a clean agent such as FM-200 (HFC-227ea) or FK-5-1-12, often as a single modular cylinder per room because the rooms are small. It leaves no water or residue on equipment.
  • Electrical, generator and transformer rooms: the same regulation names carbon dioxide (CO2) for them, which suits unoccupied rooms. See the electrical rooms page.
  • Handover file: design calculations, drawings and test report, ready for the hotel's file at Civil Defense licence renewal.

Questions procurement teams ask

Does Civil Defense require gas suppression in a hotel server room?

Yes, for hotels with occupancy over 250: computer and sensitive-equipment rooms need automatic extinguishing "using halon alternatives" (hotels regulation, Section 11/6/c, p.19).

Does the regulation name FM-200?

No. It says «الوسائل البديلة لغاز الهالون» (halon alternatives). FM-200, FK-5-1-12 and inert gases are all halon alternatives; the agent is chosen in design.

What about the hotel's electrical and generator rooms?

The same regulation names carbon dioxide for them (Section 11/6/t, p.19). CO2 systems are meant for unoccupied rooms.

Is the gas system linked to the hotel fire alarm?

Yes. We connect the control and release panel to the hotel's main fire alarm panel, and to HVAC shutdown in the protected room.

Do you offer a maintenance contract for the system?

Yes. Our maintenance contracts cover cylinders, detectors and the release panel, with a report for every visit.

Send the room size and site type

We calculate the agent quantity and send you the quotation.