Thiqat Al Tamayozثقة التميزTHIQAT AL TAMAYOZ — TALS
Modern office building in Riyadh
FM-200 — Archives & records

FM-200 fire suppression for archives, records and document centres in Riyadh

TALS supplies and installs FM-200, clean-agent and inert-gas fire-suppression systems for archive rooms, document stores and microfilm rooms in Riyadh and across Saudi Arabia.

The gas puts no water on paper or files, and our in-house engineers design every room to NFPA 2001 and ISO 14520.

What we deliver

  • Site survey of the archive room and agent quantity calculation for its volume, shelving and any raised floor.
  • Supply of FM-200, FK-5-1-12 or inert-gas systems from several international brands.
  • Installation with automatic detection, release control panel and HVAC shut-down interlock.
  • Room integrity (door fan) test before handover.
  • Maintenance contracts, and cylinder refills for the systems we installed.
  • Replacement of old Halon systems in archives and document centres.

Request an FM-200 quotation

Only name and mobile are required.

Send files (BOQ, drawings) later to info@tals.sa or WhatsApp.

Prefer to talk first?

Projects line

055 544 3168

📞 Call

info@tals.sa

The official requirement

«المركز: مركز وإدارة حفظ المستندات والوثائق والمعلومات والمعاملات والبيانات المحفوظة على الورق المقوى أو أجهزة الحاسبات الآلية ومستلزماتها كالأقراص المغناطيسية أو الميكروفيلم أو الأشرطة المغناطيسية أو غيرها من وسائل الحفظ الأخرى، كالأفلام والشرائح الشفافة وغيرها.»

A "centre" under this regulation is any place that keeps documents, records and data on paper, computers, magnetic discs, microfilm, tapes or film.

Source: Saudi Civil Defense, «لائحة شروط السلامة والحماية من الحريق في مراكز المعلومات» (Fire safety regulation for information centres), Article 1, p.2.

«١. يجب ان تشمل تجهيزات الحماية من الحريق نظام كامل للإنذار الآلي والاطفاء التلقائي بإستخدام غاز الهالون أو الغازات المغمده المناسبه التي لا تحدث تلفيات بالمكان نتيجة الاستعمال.»

Such a centre needs a complete automatic alarm and automatic extinguishing system using halon or suitable flooding gases that cause no damage.

Source: Same regulation, Article 14, item 1, p.6.

Sector specifics

  • Typical rooms: paper document stores; file rooms in government bodies, courts, universities and companies; microfilm and tape rooms; scanning and digitisation rooms.
  • Usual agent: clean agent (FM-200 or FK-5-1-12) or inert gas (IG-541 / IG-55). None of them leaves water or residue on paper or film.
  • Large archives: inert gas is often preferred, as it is not part of the Kigali HFC phase-down.
  • Public library reading halls: the public-libraries regulation asks for automatic sprinklers there; gas is for special storage rooms, decided at design.

Questions procurement teams ask

Does the information-centres regulation cover paper archives?

Yes. Article 1 defines a "centre" as one that keeps documents on paper, computers, microfilm, tapes or film.

What extinguishing system does a records centre need?

Article 14 (item 1) asks for complete automatic alarm and automatic extinguishing with halon or suitable gases that do not damage the place. Civil Defense's own site says halon is being replaced by alternative agents, so today it is designed with a clean agent or inert gas.

Do public libraries need gas suppression?

The public-libraries regulation (Article 16, p.8) asks for automatic sprinklers and dry-powder and CO2 extinguishers. Manuscript and microfilm rooms get their system at design stage.

Will the gas damage documents?

Manufacturers state that clean agents and inert gases leave no water and no residue. The gas is cleared by ventilation after discharge.

Do we need Civil Defense approval before installation?

Yes. Article 14 (item 8) says work starts only after Civil Defense and the competent bodies approve, and item 3 requires a practical test after installation in the presence of the competent body's representative.

How often must it be checked?

Article 6 makes the facility's responsible person answerable for monthly checks and tests every three months. A maintenance contract covers this.

Send the room size and site type

We calculate the agent quantity and send you the quotation.

📞 CallWhatsAppQuote