FM-200 fire suppression for bank data centres and server rooms in Riyadh

TALS supplies and installs FM-200 and clean-agent fire-suppression systems for bank data centres, disaster-recovery (DR) sites and branch server rooms in Riyadh and across Saudi Arabia.

Our in-house engineers design each system to NFPA 2001 and ISO 14520, and our maintenance visits each come with a signed report.

What we deliver

  • System design and agent quantity calculation, with the same specification for the primary data centre and the DR site on request.
  • Supply of FM-200 (HFC-227ea) and other clean-agent systems from several international brands.
  • Installation with automatic detection, release control panel and HVAC shut-down interlock.
  • Room integrity (door fan) test before handover.
  • Multi-branch maintenance contracts, with a signed report for every visit and a test log.
  • Cylinder refills for the systems we installed.
  • Replacement of old Halon and FM-200 systems.

Request an FM-200 quotation

Only name and mobile are required.

Send files (BOQ, drawings) later to info@tals.sa or WhatsApp.

Prefer to talk first?

Projects line

055 544 3168

📞 Call

info@tals.sa

The official requirement

«١. يجب ان تشمل تجهيزات الحماية من الحريق نظام كامل للإنذار الآلي والاطفاء التلقائي بإستخدام غاز الهالون أو الغازات المغمده المناسبه التي لا تحدث تلفيات بالمكان نتيجة الاستعمال.»

An information centre needs a complete automatic alarm and automatic extinguishing system using halon or suitable flooding gases that cause no damage.

Source: Saudi Civil Defense, «لائحة شروط السلامة والحماية من الحريق في مراكز المعلومات» (Fire safety regulation for information centres), Article 14, item 1, p.6. The regulation covers any centre that keeps data on computers (Article 1); whether a given bank room falls under it is Civil Defense's call.

«أنظمة الإطفاء تعمل ويتم صيانتها بشكل دوري»

Extinguishing systems must work and be maintained regularly.

Source: Salamah platform, requirement list for group 2, which includes the activity «بنوك تجارية وطنية محلية» (local commercial banks, 641911).

Sector specifics

  • Typical rooms: primary data centre, DR site, core-banking rooms, branch server rooms, ATM switch and network rooms.
  • Usual agent: FM-200 or FK-5-1-12 for small and medium rooms, because neither leaves water or residue, so equipment returns to service quickly.
  • Large halls and paper-record rooms: inert gas (IG-541 / IG-55) is often chosen.
  • Cash centres and vaults: the agent depends on the room's integrity and occupancy, decided site by site.

Questions procurement teams ask

Does SAMA require a gas suppression system?

We found no SAMA text that says so. SAMA's IT Governance Framework (3.3.5) asks for physical and environmental controls in the data centre, naming smoke detectors, fire alarms and fire extinguishers. The gas requirement comes from the Civil Defense information-centres regulation.

Does a branch server room need a fixed system?

The residential and office buildings regulation names «طفايات هالون لغرف الكمبيوتر والأجهزة الدقيقة» (halon-type extinguishers for computer rooms; section 3/C, p.15). A fixed system for a branch room is decided at design stage and with Civil Defense.

What documents do we hand over after installation and maintenance?

Drawings, the room integrity test result, commissioning documents, and a signed report for every maintenance visit. These records support internal audit and risk teams.

Which agent suits a bank server room?

FM-200 or FK-5-1-12 for small and medium rooms, inert gas for large halls. FM-200 is under a supply phase-down in the Kigali Amendment, not a ban.

How often must the system be checked?

Article 6 of the information-centres regulation makes the facility's responsible person answerable for monthly checks and tests every three months. One maintenance contract can cover all branches.

Send the room size and site type

We calculate the agent quantity and send you the quotation.